Contexte de l'analyse | Some good reasons to perform the analysis of the water that feeds your appliances. - You notice a white deposit difficult to remove on your taps, on your dishes. - Your appliances and / or fittings are to be renewed frequently - Your laundry comes out rough from the washing machine - You observe a bluish stain at the bottom of a sink |
Liste des analyses réalisées | pH, TA-TAC (carbonates), pH and TA-TAC at equilibrium, Total hardness (TH), conductivity, chlorides, iron. |
The analysis makes it possible to know the aggressive or scaling character of the supply water of my household appliances. Corrections can therefore be made to improve the quality of the water.
pH: Used to control the acidity or alkalinity of a water. A low pH (acidic) may cause degradation of the metallic elements. A high (basic) pH promotes lime deposition
Conductivity: Information on the mineralization of water, the higher the value the more the water is loaded with mineral salts.
Alkalimetric Title - Complete Alkalimetric Title (TA-TAC): Translate the carbonate alkalinity of a water.
equilibrium pH and TAC: Indicates the pH and TAC value so that the water is neither aggressive nor encrusting (chemically neutral water)
Total hardness (TH or hydrotimetric title): Corresponds to the presence of calcium and magnesium in water. High hardness promotes scaling, low hardness promotes corrosion.
Chlorides: Promotes corrosion of metallic elements
Iron: A significant presence in water can come from the degradation of metallic elements. The red coloration shows a high concentration of iron